Operation Strategy for Improving Voltage Profile and Reducing System Loss


Abstract—This paper presents an application of a coordinated
static VAr compensator (SVC) device as additional control for
the reactive power (VAr) optimization problem and analyzes the
impact on system loss and voltage profile. The coordinated SVC
model controls internal, local, and remote devices simultaneously.
It has two modes of operation: 1) voltage-control mode; and 2) Q
control mode. This paper analyzes the functions of the coordinated
SVC and implements them in the practical power systems. The
impact of VAr optimization with coordinated SVC model on loss
minimization and voltage enhancement are also discussed by
comparing it with VAr optimization with general SVC model as
well as VAr optimization without the SVC model..

 

راهبرد عملياتي بمنظور بهبود پروفيل ولتاژ و كاهش تلفات سيستم

 

چكيده

اين مقاله يك كاربرد عملي جبرانساز استاتيك توان راكتيو هماهنگ شده (SVC) بعنوان يك كنترل مكمل در مساله بهينه سازي توان راكتيو (VAR) را پيشنهاد مي كند و تاثير آن بر روي پروفيل ولتاژ و تلفات سيستم قدرت را مورد بحث و بررسي قرار مي دهد. مدل هماهنگ شده SVC تجهيزات داخلي، محلي و خارجي را بطور همزمان كنترل مي كند. و دو مد كنترلي دارد: 1) مد كنترل ولتاژ، 2) مد كنترلي Q. اين مقاله عملكردهاي SVC هماهنگ شده را بررسي كرده و آنها را بر روي سيستم هاي قدرت واقعي پياده مي كند. اثر بهينه سازي توان راكتيو با مدل هماهنگ شده SVC در مينيمم سازي تلفات و تقويت ولتاژ با مقايسه بهينه سازي توان راكتيو با مدل SVC معمولي و همچنين بهينه سازي توان راكتيو بدون مدل SVC مورد بررسي قرار گرفته است.

 

 

 

پس از پرداخت، لينك دانلود فايل براي شما نشان داده مي شود

پرداخت و دانلود

كاهش تلفات با استفاده از مدل جديد SVC

۱۳ بازديد
دسته بندي مقالات ترجمه شده
فرمت فايل doc
حجم فايل 415 كيلو بايت

پس از پرداخت، لينك دانلود فايل براي شما نشان داده مي شود

پرداخت و دانلود

LOSS REDUCTION FROM USE OF NEW SVC MODEL

Abstract-- This paper presents an application of a
flexible AC transmission system (FACTS) device as
additional control in reactive power (VAR) optimization
problem and analyzes the impact on system loss
minimization. The adopted FACTS device is a new static
VAR compensator (SVC). The general SVC consists of
internal devices, and local devices, and the operation
mode of the general SVC model is voltage control mode
only. The new SVC model controls local, remote, internal
and external devices simultaneously. It has two modes of
operation: (1) Voltage control mode; and (2) Q control
mode. This paper analyzes the functions of the new SVC,
and implements them in the practical power systems.
The impact of VAR optimization with new SVC model on
loss minimization is also discussed by comparing it with
VAR optimization with general SVC model as well as
VAR optimization without SVC model.

كاهش تلفات با استفاده از مدل جديد SVC 

 

چكيده

اين مقاله كاربرد يكي از تجهيز FACTS بعنوان كنترل مكمل در مساله بهينه سازي توان راكتيو ارائه مي دهد و اثر آن بر روي مينيمم سازي تلفات سيستم را بررسي مي كند. اين تجهيز FACTS يك جبرانساز توان وار ايستاي جديد SVC مي باشد. يك SVC معمولي شامل تجهيزات داخلي، تجهيزات محلي و مد بهره برداري SVC تنها مد كنترلي ولتاژ مي باشد. مدل جديد SVC جديد تجهيزات محلي، دور، داخلي و خارجي را بطور همزمان كنترل مي كند. اين دو مد بهره برداري دارد: (1) مد كنترلي ولتاژ (2) مد كنترلي Q. اين مقاله عملكرد SVC جديد را تحليل مي كند و آن را در سيستم هاي واقعي پياده مي كند. اثر بهينه سازي VAR با مدل SVC جديد براي مينيمم سازي تلفات همچنين با مقايسه آن با بهينه سازي VAR با مدل SVC معمولي همچنين بدون SVC مورد بررسي قرار گرفت.

 

پس از پرداخت، لينك دانلود فايل براي شما نشان داده مي شود

پرداخت و دانلود